MASS SPECTROMETRY INSTRUMENTS
Instruction and Services
Instruments and Services: The MS Facilities is well equipped to do mass spectrometric analysis of macromolecules such as proteins, peptides, oligonucleotides, lipids, and carbohydrates and small molecules with separation capabilities using chromatographic techniques such as GC, LC.
Services:
Mass Spectrometers | Ionization | Mass Analyzer | Application |
Q-TOF micro (Waters Micromass) | ESI APCI | Quadruple-TOF | Nominal mass measurements Accurate mass measurements (5 ppm) Elemental composition analyses Tandem mass measurements Protein characterization |
UltrafleXtreme-MALDI TOF-TOF-Imaging | MALDI | TOF-TOF | Mass determinations of intact proteins, peptides, oligonuclotides, glycolipids, carbohydrates and other small organic molecules Protein identification and characterization Protein post-translational modification characterization Peptide de novo sequencing Protein quantitative analysis MALDI imaging biomarker discovery and identification |
LC-API 3200 (Sciex) |
ESI APCI | Triple Quadruple | Nominal mass measurements Tandem mass measurements Liquid chromatographic separations Quantitative analyses |
QP5050A GCMS (Shimadzu) |
EI, NCI, PCI | Single Quadruple | Nominal mass measurements Gas chromatographic separations Quantitative analyses |
The Bruker Daltonics ultrafleXtreme MALD TOF-TOF-Tissue Imaging
The UltrafleXtreme MALDI TOF-TOF is a proteomics analyzer that utilizes tandem TOF technology and Proteinscape software to provide high-throughput protein and biomarker identification and discovery with high confidence.
The Waters Micromass Q-Tof micro Mass Spectrometer
The Micromass Q-Tof micro mass spectrometer coupled with Waters 2695 HPLC can provide both routine structural elucidation of small molecules and biomacromolecules as well as exact mass measurements with both Electrospray Ionization (ESI) and Atmospheric Pressure Chemical Ionization (APCI) techniques. The instrument also features a quadruple mass filter and collision cell for MS/MS analyses and is equipped with a Waters Alliance HPLC and an nanoAcquity UPLC for separation.
API 3200 LC/MS/MS System
The API 3200 LC/MS/MS system is a triple quadruple mass spectrometer coupled with an Agilent 1200 series HPLC and UV-DAD used ideally for qualitative and quantitative analysis of chemical and biological molecules (M/Z < 1800 Da).
The Shimadzu GCMS QP-5050 Aquadrupole GC/MS System
This instrument has both electron ionization (EI) and chemical ionization (positive CI and negative CI) capabilities with high sensitivities. A mixture can be separated by gas chromatography and analyzed by a single quadruple analyzer.
Contact Us
Department of Chemistry
Office Hours:
Monday - Friday
8:30 a.m. - 5:15 p.m.
Chair
Associate Chair
Directors of Undergraduate Studies
Joan Mutanyatta-Comar
Director of Graduate Studies
Associate Director of Graduate Studies
Office / Delivery Address
Department of Chemistry
Georgia State University
50 Decatur St. SE
262 Natural Science Center
Atlanta, GA 30303-2924
Phone: 404-413-5554
(Only for stockroom concerns)
Hours: Monday - Friday
10 a.m. - 12 p.m., 2 - 4 p.m.
USPS Mailing Address
Department of Chemistry
Georgia State University
P.O. Box 3965
Atlanta, GA 30302-3965